Gold Member Since 2015
Audited Supplier
Yongjia Borra Pump & Valve Manufacture Co., Ltd.

Fire Fighting Pump, High Pressure Pump, Fire Pump manufacturer / supplier in China, offering High Pressure Fire Fighting Water Electric Pump, Portable Pump, Water Supply Fire Fighting System Diesel Electric Jockey Fire Firghting Pump and so on.

(/ )

Supplier Homepage Product Centrifugal Pump High Pressure Fire Fighting Water Electric Pump

High Pressure Fire Fighting Water Electric Pump

Purchase Qty.:
(Pieces)
1-9 10+
FOB Unit Price: US $500 US $7,000
Purchase Qty. (Pieces) FOB Unit Price
1-9 US $500
10+ US $7,000
Get Latest Price
Production Capacity: 1000
Transport Package: Wood Case
Payment Terms: T/T, D/P

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: XBD-(I)
  • Type: Handheld
  • Certification: ISO, SGS
  • Pressure Pump: High Pressure Pump
  • Vertical 1-Stage & 1-Priming Pump: Vertical Pump
  • Vertical 1-Stage Pump: Pump
  • Fire Fight Pump: Fire Fight Diesel Pump
  • Specification: ISO
  • HS Code: 8413810090
  • Pressure Medium: Water
  • Position of Pump Shaft: Vertical Edge
  • 1-Stage Pump: Fire Pump
  • Pump: Booster Pump
  • Electric Pump: Centrifugal Pump
  • 1-Stage & 1-Priming Pump: 1-Priming Pump
  • Trademark: Borra
  • Origin: Wenzhou
Product Description
High Pressure Fire Fighting Water Electric Pump

XBDL vertical 1stage & 1priming pumps system, used to transfer clear water and similar liquids with similar physical & chemical properties, without solid particles, applied and suitable in pressure boosted water supply in fire fight systems, industrial and municipal water supply and drain, high-building architecture pressure boosted water supply, remote water supply, heating, bathrooms, boiler cold & hot water circulation, pressure boosted air-conditioning system water supply and peripheral facilities.
   XBD-L fire fight pumps system's performance and technical parameters comply with GB6245-1998 "Performance requirements and test methods for fire pumps", and obtains certificates from "China National Fire Fight Equipment Quality Supervision & Testing Center".
   Computer design and optimized processing, strong technical power, rich manufacture experiences and perfect test methods ensure stable and reliable quality.

Characteristics:
1. Compact structure, small, nice, vertical installation, less area for installation needed, gravity on feet, stable running and long life.
2. Stable running, little noise, highly concentric components.
3. Advanced hydraulic model, high efficiency and performance.
4. The superior mechanical shaft seal, highly endurable against friction, no leak, long life.
5. The pump inlet and outlet are on a same horizontal line, same sizes, easy to install and uninstall.
6. Easy to maintain, pipes uninstall is not needed, you only need take off pump cap nuts, then take out motor and transmission elements, before maintaining.

Technical parameters:
flow: 5-100L/S;
pressure: 0.10-1.25Mpa;
power: 1.1-250KW;
rotation speed: 980-2900r/min;
diameter: φ50-φ300;
temperature range:≤80ºC.
Model numberFlow Q
(L/s)
Outlet pressure
(MPa)
Rotation speed n
(r/min)
Power P
(Kw)
Efficiency η
(%)
XBD3.0/5-50(65)50.302900463
XBD3.2/5-50(65)0.32
XBD3.4/5-50(65)0.34
XBD4.6/5-50(65)50.4629007.558
XBD4.8/5-50(65)0.48
XBD5.0/5-50(65)0.50
XBD7.6/5-50(65)50.7629001550
XBD7.8/5-50(65)0.78
XBD8.0/5-50(65)0.80
XBD11/5-50(65)51.1029003040
XBD12/5-50(65)1.20
XBD12.5/5-50(65)1.25
XBD3.0/10-65(80)100.3029007.571
XBD3.2/10-65(80)0.32
XBD3.4/10-65(80)0.34
XBD4.6/10-65(80)100.4629001567
XBD4.8/10-65(80)0.48
XBD5.0/10-65(80)0.50
XBD7.6/10-65(80)100.7629002259
XBD7.8/10-65(80)0.78
XBD8.0/10-65(80)0.80
XBD11/10-65(80)101.1029003754
XBD12/10-65(80)1.20
XBD12.5/10-65(80)1.25
XBD3.0/25-80(100)250.3029001576
XBD3.2/25-80(100)0.32
XBD3.4/25-80(100)0.34
XBD4.6/25-80(100)250.4629002274
XBD4.8/25-80(100)0.48
XBD5.0/25-80(100)0.50
XBD7.6/25-80(100)250.7629003769
XBD7.8/25-80(100)0.78
XBD8.0/25-80(100)0.80
XBD11/25-80(100)251.1029007569
XBD12/25-80(100)1.20
XBD12.5/25-80(100)1.25
XBD13/25-80(100)251.3029009057
XBD14/25-80(100)1.40
XBD15/25-80(100)1.50
XBD3.0/45-100(125)450.3029002273
XBD3.2/45-100(125)0.32
XBD3.4/45-100(125)0.34
XBD4.6/45-100(125)450.4629003777
XBD4.8/45-100(125)0.48
XBD5.0/45-100(125)0.50
XBD7.6/45-100(125)450.7629005580
XBD7.8/45-100(125)0.78
XBD8.0/45-100(125)0.80
XBD11/45-100(125)451.1029009070
XBD12/45-100(125)1.20
XBD12.5/45-100(125)1.25
XBD2.8/55-150(200)550.2814503078
XBD3.0/55-150(200)0.30
XBD3.2/55-150(200)0.32
XBD4.6/55-150(200)550.4614504575
XBD4.8/55-150(200)0.48
XBD5.0/55-150(200)0.50
XBD7.6/55-150550.7629007576
XBD7.8/55-1500.78
XBD8.0/55-1500.80
XBD11/55-150551.10290011073
XBD12/55-1501.20
XBD12.5/55-1501.25
XBD13/55-150451.30290011080
XBD14/55-1501.40
XBD15/55-1501.50
XBD4.6/100-2001000.4614507581
XBD4.8/100-2000.48
XBD5.0/100-2000.50
XBD3.0/150-2501500.3014507580
XBD3.2/150-2500.32
XBD3.4/150-2500.34
XBD4.6/140-2501400.4614509072
XBD4.8/140-2500.48
XBD5.0/140-2500.50
XBD2.4/200-3002000.249707581
XBD2.6/200-3000.26
XBD2.8/200-3000.28
XBD2.8/200-300(350)2000.2814509084
XBD3.0/200-300(350)0.30
XBD3.2/200-300(350)0.32
XBD4.0/200-3002000.4097013284
XBD4.2/200-3000.42
XBD4.4/200-3000.44
XBD4.6/160-3001600.46145011078
XBD4.8/160-3000.48
XBD5.0/160-3000.50
XBD4.6/200-3502000.46145016083
XBD4.8/200-3500.48
XBD5.0/200-3500.50
XBD2.8/300-4003000.28145013276
XBD3.0/300-4000.30
XBD3.2/300-4000.32
XBD2.8/330-5003300.28145016078
XBD3.0/330-5000.30
XBD3.2/330-5000.32


High Pressure Fire Fighting Water Electric Pump

Start, running and stop 
Start
1. First of all, pour water into pipes, to make the pump and inlet pipe filled by waterThe pipes shall be sealed, no air leaked. (no-water inside start is forbidden) 
2. Close globe valve and cock on outlet pipe, to reduce start currency.
3. Rotate the rotor by hand, lubricate the bearing and check pump impeller, seal ring, if it cannot rotate, you shall not start.
4. Try to start, motor rotation direction shall be as same as the arrow direction on the pump. 
5. When rotor works normally, open gradually the outlet globe valve, adjust for the work conditions required.
Running
1. Observe the reading in meters, keep it running around the flow and head shown on the nameplate.
2. Regularly check, motor currency value shall not exceed rated currency value.
3. Pump bearing temperature shall not exceed 75ºC, and shall not be 35ºC higher than ambient environment.
4. To start, loosen stuff cap. Adjust later when started.
5. In case fragile component abrasion, replace in time.
6. When any abnormal happens, immediately stop and check.
Stop
1. Close the globe valve on outlet pipe, close vacuum gauge cock.
2. Stop motor, and close pressure cock.
3. In Winter, drain liquid in the pump completely to avoid frozen cracks.
4. When you will not use it for a long time, uninstall the pump, clean and lubricate.

Troubleshooting 

 
FaultCauseSolution
Pump cannot suck water, pressure gauge & vacuum gauge vibrating 1. Insufficient water pouring 
2. Leak between pipe and meter 
3. Suction is too high 
1, check leak in bottom valve. 
2, Tighten the leaked part 
3, reduce suction 
Pump cannot suck, high vacuum shown in vacuum gauge1, bottom valve closed or jammed 
2, Too great water suction resistance 
3, filter jammed 
1, check bottom valve
2, replace water suction pipe
3, clear off filter
Pressure gauge works, no water outcome1. Great outlet water pipe resistance
2. Wrong rotation direction 
3. Outlet pipe valve closed
4. impeller jammed 
1. check or shorten water pipe 
2, check motor, adjust 
3, open valve and clear off impeller
Cannot reach designed flow1. air sucked 
2. Water level drops, submerged depth is not enough 
3. impeller jammed 
4. rotor torn and worn 
1, check leak part and clear off 
2, prolong water inlet pipe, increase submerged depth
3, uninstall and clear off 
4, replace seal ring 
Great pump power consumption1. Stuff tightened, overheated 
2. Great flow 
3. Collision between rotor and case 
4. Pump shaft bearing abrasion 
5. Pump shaft misplaced
1. loosen slightly
2. reduce globe valve opening
3. adjust 
4. replace bearing 
5. replace or adjust 
Great pump vibration 1. impeller partially jammed 
2. impeller damaged 
3. little flow 
4. non-concentric between pump shaft and motor.
5,bearing damaged 
6, gas etching
1. Uninstall and clear off 
2, replace 
3, increase opening 
4, adjust
5, replace  
6, change suction inlet position 

Application range
Mainly applied in fire fight system pipes pressure boosted water supply, industrial and municipal water supply and drain, high-building architecture pressure boosted water supply, remote water supply, heating, bathrooms, boiler cold & hot water circulation, pressure boosted air-conditioning system water supply and peripheral facilities.

High Pressure Fire Fighting Water Electric PumpHigh Pressure Fire Fighting Water Electric PumpHigh Pressure Fire Fighting Water Electric PumpHigh Pressure Fire Fighting Water Electric Pump
Send your message to this supplier
Avatar
Miss Karol Hu
Manager
*From:
To: Miss Karol Hu
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now