Jockey Fire Fighting Boosting Water Pump

Product Details
Customization: Available
After-sales Service: Worldwide
Warranty: 1 Year
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14001
  • Jockey Fire Fighting Boosting Water Pump
  • Jockey Fire Fighting Boosting Water Pump
  • Jockey Fire Fighting Boosting Water Pump
  • Jockey Fire Fighting Boosting Water Pump
  • Jockey Fire Fighting Boosting Water Pump
  • Jockey Fire Fighting Boosting Water Pump
Find Similar Products

Basic Info.

Model NO.
XBC
Air Engine Type
Diesel Engine
Theory
Gas-hydraulic Hybrid Type
Transmission
Direct Connection Transmission
Structure
The Slide
Fire Pump
Water Fire Pump
Pump
Fire Fighting Pump
Water Pump
Booster Pump
Pump System
Water Fire Pump
Transport Package
Wood Case
Specification
SGS
Trademark
Borra
Origin
Wenzhou
HS Code
841330900
Production Capacity
500

Product Description

Jockey Fire Fighting Boosting Water Pump 

Booster Regulator Water Supply Equipment is booster regulate equipment, which manufactured based on National Building Standard 98s205 design. The device consists of a diaphragm pressure tank, booster pump, electric control box, instrumentation and piping accessories, and other components, suitable for multi-story and high-rise buildings and booster requirements for fire hydrant water supply systems and automatic water spraying fire-extinguishing systems, and other fire-fighting and water supply system.

Jockey Fire Fighting Boosting Water PumpPump Feature : 

1, With the pump, electric control cabinet, diaphragm type pressure tanks, pipes, four-in-one combination network, and accompanied with the isolator without pre-embedded holes, designers can easily select device model and size, by counting Parameters. Electric Designers do not need to design the control circuit, only need to design for the cable line to pumping stations and the device. Choose convenience, can greatly shorten the design cycle for designers and construction time for builders.
2, Diaphram pressure tank disposable inflatable, durable lifetime. Water vapor isolation can prevent the pollution of water.
3, Small occupation area, low investment, automatic operation.
4, Equipment with the dual power connector, dual power automatic (manual) switch, the device can be made according to the design requirements.
5, with automatic protection and failover capabilities. Any failure of a pump (electrical failure or hydraulic failure) can start the standby pump.
6, can be connected with the fire center (according to design).
7, can choose the tank, regulator manner based on customer needs and control functions.
8, the main electrical accessories using domestic or brand-name products, reliable and stable operation.
Jockey Fire Fighting Boosting Water Pump

Pump Characteristic :


1- Three start modes:
A- Manual start: switch between manual, automatic interlink by hand, manual start:
B- automatic/manual mode: start to fail to warn 5-10-15S;
C-  Emergency manual direct start: in failure, emergency manual start.

2- Automatic run:
when pump receives fire signals if motor fire pump electric power supply system is off or phase loss, and pump cannot start normally, diesel engine fire pump will automatically start, as soon as the electric power supply system recovers or motor pump can start normally, it will be switched to the motor pump automatically.
3- automatic stop:
when the fire signal is off, the diesel engine fire pump will delay and stop.
4- Storage battery self-charging:
storage battery can be charged by industrial power diesel engine charging motor.
5- Perfect indication system:
prepared start, manual start, automatic start, run, stop storage battery charging, ultra-speed, diesel engine lubricant oil pressure too low, booster oil pressure too low, diesel engine lubricant oil temperature too low, diesel engine cooling water temperature too low, storage battery voltage too low, fuel oil level too low (shortage).
6- Perfect warning or safeguard system:
3-fail start warning, ultra-speed warning, lubricant oil warning, booster oil warning, cooling water temperature warning, lubricant oil warning, automatic charging system warning, storage battery warning, storage battery warning, oil level warning.
7- Good indicators:
diesel engine lubricant oil pressure, diesel engine rotation speed, storage battery charging current, storage battery charging voltage.
8-  Direct coupling:
the diesel engine is connected with a pump with a coupler, compact structure, little faults, little faults, little vibration, easy to install.
9- Pressure, flow range:
IS series 1-stage 1-priming, S\SOW series 1-stage 2-priming, TSWA\D series multi-stage pump.
10- Flow, pressure regulation:
diesel engine pump, with a mechanical regulator or electronic regulator, when pump flow, head are not correct, you can change the diesel engine rotation speed.
11- Water preheat system:
AC220V cooling water preheat system, to keep work under 50C.
12- Storage batteries: a standby system.
13- maintenance-free storage batteries: it is not needed to refill liquids frequently.
14- Automatic timed monitor test: standby fire system, automatic test, and warning.
Note: designed as per requirements.Jockey Fire Fighting Boosting Water Pump

Pump Application

 

 1- Drinking water supply in ordinary residential buildings, commercial buildings, residential areas.

 2- Firewater supply in high building

 3- Production and life water in some industrial and mining enterprises

 4-  Sewage treatment system

 5- Water irrigation and spring irrigation
 


Configuration:

1, pump: IS series of single-stage single-suction, S, SOW series 1-stage dual-suction, TSWA, D series multi-stage.
2, diesel engine: 1-cylinder, 2-cylinder, 3-cylinder, 4-cylinder, 6-cylinder, 8-cylinder, 12-cylinder diesel engine.
3, rotation speed: 1500r/min, 1800r/min, 2400r/min, 3000r/min.
4, accessories: Filter muter, cooling system, fuel tank, seat, heat-exhaust water tank, storage battery, and charger. (Preheat system)
5, control cabinet: microcomputer, PLC, sensors, automatic control cabinet.



Work range:

Ambient pressure :> 90KPa
Ambient temperature: 50C-400C
relative humidity:≤80%
In abnormal conditions, greater diesel engine power is needed to match the pump.



Jockey Fire Fighting Boosting Water Pump


Technical Parameters:

Flow range: 10-800L/S
Pressure range: 0.2-2.2MPA
Rotation speed: 1500r/min    1800 r/min    2400 r/min    3000 r/min
Diesel engine pump Rate flow
m3/h
Rate head
m
Rated rotation speed
r/min
Pump type
XBC8.0/13.9 30-50-60 84-80-75 2900 IS80-50-250
XBC7.0/13.0 47 70 2900 IS80-50-250A
XBC6.0/12.2 44 60 2900 IS80-50-250B
XBC8.5/11.7 42 85 2900 IS80-50-315B
XBC11.0/13. 47 110 2900 IS80-50-315A
XBC12.5/13.9 30-50-60 128-125-123 2900 IS80-50-315
XBC5.0/27.8 60-100-120 54-50-47 2900 IS100-65-200
XBC6.0/23.9 86 60 2900 IS100-65-250B
XBC7.0/25.8 93 70 2900 IS100-65-250A
XBC8.0/27.8 60-100-120 87-80-75 2900 IS100-65-250
XBC10.0/25.0 90 100 2900 IS100-65-315B
XBC5.0/55.6 120-200-240 58-50-45 2900 IS125-100-200
XBC6.0/48.1 173 60 2900 IS125-100-250B
XBC12.5/27.8 60-100-120 133-125-118 2900 IS100-65-315
XBC8.0/55.6 120-200-20 87-80-72 2900 IS125-100-250
XBC12.5/55.6 120-200-240 133-125-120 2900 IS125-100-315
XBC11.0/52.8 190 110 2900 IS125-100-315A
XBC9.2/48.1 173 92 2900 IS125-100-315B
XBC5.0/111 240-400-460 55-50-45 1450 IS200-150-400
XBC5.0/28 100 50 1450 IS125-100-400
XBC5.0/28 200 50 1450 IS150-125-400
XBC4.6/10 30-36-42 50-46-40 1450 75TSWA×4
XBC5.7/10 30-36-42 62-57-50 1450 75TSWA×5
XBC6.9/10 30-36-42 75-69-60 1450 75TSWA×6
XBC8.0/10 30-36-42 87-80-70 1450 75TSWA×7
XBC9.2/10 30-36-42 100-92-80 1450 75TSWA×8
XBC10.3/10 30-36-42 112-103-90 1450 75TSWA×9
XBC6.2/19.2 62-69-80 64-62-56 1450 100TSWA×4
XBC7.8/19.2 62-69-80 81-78-70 1450 100TSWA×5
XBC9.3/19.2 62-69-80 97-93-84 1450 100TSWA×6
XBC10.9/19.2 62-69-80 113-109-98 1450 100TSWA×7
XBC6.4/25 72-90-108 69-64-60 1450 125TSWA×3
XBC8.6/25 72-90-108 92-86-80 1450 125TSWA×4
XBC10.8/25 72-90-108 115-108-100 1450 125TSWA×5
XBC6.0/43 119-155-191 65-60-55 1480 150TSWA×2
XBC9.0/43 119-155-191 97-90-82 1480 150TSWA×3
XBC12.0/43 119-155-191 129-120-109 1480 150TSWA×4
XBC8.6/77.8 190-280-346 95-86-77 1480 200D1-43×2
XBC12.9/77.8 190-280-346 142-129-115 1480 200D1-43×3
XBC12.0/125 400-450-500 123-120-114 1480 D450-60III×2
XBC11.4/139 450-500-550 120-114-108 1480 D500-57×2
XBC12.0/200 550-720-850 132-120-108 1480 D720-62×2
XBC5.0/60 150-216-260 59-50-45 1480 D216-25×2
XBC7.5/60 150-216-260 88-75-67 1480 D216-25×3
XBC10.0/60 150-216-260 118-100-90 1480 D216-25×4
XBC12.5/60 150-216-260 147-125-112 1480 D216-25×5
XBC6.5/134 360-485-612 71-65-56 1450 250S65
XBC9.0/219 590-790-936 93-90-82 1450 300S90
XBC7.8/210 576-756-918 86-78-70 150 300S90A
XBC6.7/200 540-720-900 72-67-57 1450 300S90B
XBC5.8/219 576-790-972 65-58-50 1450 300S58
XBC5.0/204 529-735-893 55-50-42 1450 300S58A
XBC12.5/351 850-1260-1660 140-125-100 1450 350S125
XBC11.2/328 787-1181-1538 120-112-86 1450 350S125A
XBC9.6/305 697-1098-1363 106-96-77 1450 350S125B
XBC7.5/351 972-1260-1440 80-75-65 1450 350S75
XBC6.5/325 900-1170-1332 70-65-56 1450 350S75A
XBC5.5/300 813-1080-1202 59-55-46 1450 350S75B

Jockey Fire Fighting Boosting Water Pump
Pump Operation

1- Do not operate a pump without having read and understood its Operations Manual.
2- Do's  Always disconnect the negative battery cable before working on any pump.
3- Make sure all hose joints are properly connected before starting the pump.
4- Level the pump using jack stands or cribbing.
5- Install cribbing or support when using 8" or larger suction and discharge hoses.
6- Allow the engine or motor to warm up before raising the level to operate speed.
7- Raise and lower engine speed gradually.
8- Consult with us if operating an engine or motor over 1800 RPM.
9- Service diesel engines every 250 hours of running time.
10- Open drain valves on volute and non-return valves after shutting down a pump in freezing weather (ice can form and expand, possibly causing damage).
11- Take lines apart away from your body in case any remaining liquids spray.
12- Don't touch the air compressor outlet line. It can be a hot surface!
13- Don't block airflow to the engine radiator (prevents overheating).
14- Don't pump liquids with a pH other than 7 (neutral). Internal corrosion may occur.
15- Don't pump heavy abrasive material. Internal corrosion may occur.
16- Don't run a diesel engine to the point of running out of fuel. The fuel delivery system will need to be bled prior to re-starting the engine.
17- Don't open the radiator cap while the engine is still warm.

  
Product Sustainability

We are committed to providing sustainable products and solutions with all of our pumps and products.  We offer tailored pump system design, with the right size and drive equipment for every job, to reduce unnecessary power and materials.

Automated pump systems save energy and provide cleaner air and a healthier environment. 

1- Exhaust scrubbers for cleaner air
2- Biodegradable oil to help reduce potential damage to the environment
3- Critically silenced enclosures for reduced noise pollution
4- Office Sustainability
5- Recycling initiatives
6- Increased safety awareness
7- 50% paper reduction by year-end


Jockey Fire Fighting Boosting Water Pump
Troubleshooting 
 
Fault Cause Solution
The pump cannot suck water, pressure gauge & vacuum gauge vibrating  1. Insufficient water pouring 
2. Leak between pipe and meter 
3. Suction is too high 
1, check a leak in the bottom valve. 
2, Tighten the leaked part 
3, reduce suction 
The pump cannot suck, high vacuum is shown in the vacuum gauge 1, bottom valve closed or jammed 
2, Too great water suction resistance 
3, filter jammed 
1, check bottom valve
2, replace water suction pipe
3, clear off the filter
Pressure gauge works, no water outcome 1. Great outlet water pipe resistance
2. Wrong rotation direction 
3. Outlet pipe valve closed
4. impeller jammed 
1. check or shorten water pipe 
2, check the motor, adjust 
3, open the valve and clear off the impeller
Cannot reach designed flow 1. air sucked 
2. Water level drops, submerged depth is not enough 
3. impeller jammed 
4. rotor torn and worn 
1, check leak part and clear off 
2, prolong water inlet pipe, increase the submerged depth
3, uninstall and clear off 
4, replace seal ring 
Great pump power consumption 1. Stuff tightened, overheated 
2. Great flow 
3. Collision between rotor and case 
4. Pump shaft bearing abrasion 
5. Pump shaft misplaced
1. loosen slightly
2. reduce globe valve opening
3. adjust 
4. replace bearing 
5. replace or adjust 
Great pump vibration  1. impeller partially jammed 
2. impeller damaged 
3. little flow 
4. non-concentric between pump shaft and motor.
5, bearing damaged 
6, gas etching
1. Uninstall and clear off 
2, replace 
3, increase opening 
4, adjust
5, replace  
6, change suction inlet position 

Borra Technology Co., Ltd.

Borra Technology co., Ltd., founded in 1995, owns a top-rank design, production, sales, and service team, and modern production lines, to manufacture various self-priming pumps, movable diesel pumps, diesel Self-Priming dirt drain pumps, diesel fire pumps units, diesel mini-pumps.
Jockey Fire Fighting Boosting Water PumpCertificate :

Jockey Fire Fighting Boosting Water Pump
Services:

1. One year or 1000 working hours guarantee of the whole machine except for wear parts;
2. Technical support by email the whole day;
3. Calling service;
4. User's manual available;
5. Installation guide for clients from both China and abroad;
6. Maintenance and replacement service;


FAQ:

Q1: Are you a reliable company?
A1: Bora is located in Wenzu, a beautiful city in Zhejiang Province, China. we have many years of manufacturing experience,
we can supply all types of fire protection solutions, Drainage and sewage solution, and other pump products.
We have an independent factory and trade office.

Q2: how to deliver the portable diesel water pump
A2: We can offer our equipment by containers or bulk ship.

Q3: How to pay for the portable Diesel water pump?
A3: We can accept T/T, L/C and soon

Q4: why choose borra company?
A4: We have an independent factory and foreign trade office. so we can design high-quality portable generators
and water pumps according to clients requirements and our price is reasonable. 

Q5: What information should I offer to get a pump solution?
A5:
Head:     m
 Flow:    m3/h
Max Solid size:    mm
Particle shape (smooth or sharp):
Medium pH level:
Specific Gravity of the Medium:
Temperature:
Drive Type:
Power supply: Electric or Diesel
Voltage and Frequency of the Motor: 


Contact Us
If you are interested in our products or have any questions about our products, we are very honored to serve you.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier