Model number | Flow Q (L/s) |
Outlet pressure (MPa) |
Rotation speed n (r/min) |
Power P (Kw) |
Efficiency η (%) |
XBD3.0/5-50(65) | 5 | 0.30 | 2900 | 4 | 63 |
XBD3.2/5-50(65) | 0.32 | ||||
XBD3.4/5-50(65) | 0.34 | ||||
XBD4.6/5-50(65) | 5 | 0.46 | 2900 | 7.5 | 58 |
XBD4.8/5-50(65) | 0.48 | ||||
XBD5.0/5-50(65) | 0.50 | ||||
XBD7.6/5-50(65) | 5 | 0.76 | 2900 | 15 | 50 |
XBD7.8/5-50(65) | 0.78 | ||||
XBD8.0/5-50(65) | 0.80 | ||||
XBD11/5-50(65) | 5 | 1.10 | 2900 | 30 | 40 |
XBD12/5-50(65) | 1.20 | ||||
XBD12.5/5-50(65) | 1.25 | ||||
XBD3.0/10-65(80) | 10 | 0.30 | 2900 | 7.5 | 71 |
XBD3.2/10-65(80) | 0.32 | ||||
XBD3.4/10-65(80) | 0.34 | ||||
XBD4.6/10-65(80) | 10 | 0.46 | 2900 | 15 | 67 |
XBD4.8/10-65(80) | 0.48 | ||||
XBD5.0/10-65(80) | 0.50 | ||||
XBD7.6/10-65(80) | 10 | 0.76 | 2900 | 22 | 59 |
XBD7.8/10-65(80) | 0.78 | ||||
XBD8.0/10-65(80) | 0.80 | ||||
XBD11/10-65(80) | 10 | 1.10 | 2900 | 37 | 54 |
XBD12/10-65(80) | 1.20 | ||||
XBD12.5/10-65(80) | 1.25 | ||||
XBD3.0/25-80(100) | 25 | 0.30 | 2900 | 15 | 76 |
XBD3.2/25-80(100) | 0.32 | ||||
XBD3.4/25-80(100) | 0.34 | ||||
XBD4.6/25-80(100) | 25 | 0.46 | 2900 | 22 | 74 |
XBD4.8/25-80(100) | 0.48 | ||||
XBD5.0/25-80(100) | 0.50 | ||||
XBD7.6/25-80(100) | 25 | 0.76 | 2900 | 37 | 69 |
XBD7.8/25-80(100) | 0.78 | ||||
XBD8.0/25-80(100) | 0.80 | ||||
XBD11/25-80(100) | 25 | 1.10 | 2900 | 75 | 69 |
XBD12/25-80(100) | 1.20 | ||||
XBD12.5/25-80(100) | 1.25 | ||||
XBD13/25-80(100) | 25 | 1.30 | 2900 | 90 | 57 |
XBD14/25-80(100) | 1.40 | ||||
XBD15/25-80(100) | 1.50 | ||||
XBD3.0/45-100(125) | 45 | 0.30 | 2900 | 22 | 73 |
XBD3.2/45-100(125) | 0.32 | ||||
XBD3.4/45-100(125) | 0.34 | ||||
XBD4.6/45-100(125) | 45 | 0.46 | 2900 | 37 | 77 |
XBD4.8/45-100(125) | 0.48 | ||||
XBD5.0/45-100(125) | 0.50 | ||||
XBD7.6/45-100(125) | 45 | 0.76 | 2900 | 55 | 80 |
XBD7.8/45-100(125) | 0.78 | ||||
XBD8.0/45-100(125) | 0.80 | ||||
XBD11/45-100(125) | 45 | 1.10 | 2900 | 90 | 70 |
XBD12/45-100(125) | 1.20 | ||||
XBD12.5/45-100(125) | 1.25 | ||||
XBD2.8/55-150(200) | 55 | 0.28 | 1450 | 30 | 78 |
XBD3.0/55-150(200) | 0.30 | ||||
XBD3.2/55-150(200) | 0.32 | ||||
XBD4.6/55-150(200) | 55 | 0.46 | 1450 | 45 | 75 |
XBD4.8/55-150(200) | 0.48 | ||||
XBD5.0/55-150(200) | 0.50 | ||||
XBD7.6/55-150 | 55 | 0.76 | 2900 | 75 | 76 |
XBD7.8/55-150 | 0.78 | ||||
XBD8.0/55-150 | 0.80 | ||||
XBD11/55-150 | 55 | 1.10 | 2900 | 110 | 73 |
XBD12/55-150 | 1.20 | ||||
XBD12.5/55-150 | 1.25 | ||||
XBD13/55-150 | 45 | 1.30 | 2900 | 110 | 80 |
XBD14/55-150 | 1.40 | ||||
XBD15/55-150 | 1.50 | ||||
XBD4.6/100-200 | 100 | 0.46 | 1450 | 75 | 81 |
XBD4.8/100-200 | 0.48 | ||||
XBD5.0/100-200 | 0.50 | ||||
XBD3.0/150-250 | 150 | 0.30 | 1450 | 75 | 80 |
XBD3.2/150-250 | 0.32 | ||||
XBD3.4/150-250 | 0.34 | ||||
XBD4.6/140-250 | 140 | 0.46 | 1450 | 90 | 72 |
XBD4.8/140-250 | 0.48 | ||||
XBD5.0/140-250 | 0.50 | ||||
XBD2.4/200-300 | 200 | 0.24 | 970 | 75 | 81 |
XBD2.6/200-300 | 0.26 | ||||
XBD2.8/200-300 | 0.28 | ||||
XBD2.8/200-300(350) | 200 | 0.28 | 1450 | 90 | 84 |
XBD3.0/200-300(350) | 0.30 | ||||
XBD3.2/200-300(350) | 0.32 | ||||
XBD4.0/200-300 | 200 | 0.40 | 970 | 132 | 84 |
XBD4.2/200-300 | 0.42 | ||||
XBD4.4/200-300 | 0.44 | ||||
XBD4.6/160-300 | 160 | 0.46 | 1450 | 110 | 78 |
XBD4.8/160-300 | 0.48 | ||||
XBD5.0/160-300 | 0.50 | ||||
XBD4.6/200-350 | 200 | 0.46 | 1450 | 160 | 83 |
XBD4.8/200-350 | 0.48 | ||||
XBD5.0/200-350 | 0.50 | ||||
XBD2.8/300-400 | 300 | 0.28 | 1450 | 132 | 76 |
XBD3.0/300-400 | 0.30 | ||||
XBD3.2/300-400 | 0.32 | ||||
XBD2.8/330-500 | 330 | 0.28 | 1450 | 160 | 78 |
XBD3.0/330-500 | 0.30 | ||||
XBD3.2/330-500 | 0.32 |
Fault | Cause | Solution |
Pump cannot suck water, pressure gauge & vacuum gauge vibrating | 1. Insufficient water pouring 2. Leak between pipe and meter 3. Suction is too high |
1, check leak in bottom valve. 2, Tighten the leaked part 3, reduce suction |
Pump cannot suck, high vacuum shown in vacuum gauge | 1, bottom valve closed or jammed 2, Too great water suction resistance 3, filter jammed |
1, check bottom valve 2, replace water suction pipe 3, clear off filter |
Pressure gauge works, no water outcome | 1. Great outlet water pipe resistance 2. Wrong rotation direction 3. Outlet pipe valve closed 4. impeller jammed |
1. check or shorten water pipe 2, check motor, adjust 3, open valve and clear off impeller |
Cannot reach designed flow | 1. air sucked 2. Water level drops, submerged depth is not enough 3. impeller jammed 4. rotor torn and worn |
1, check leak part and clear off 2, prolong water inlet pipe, increase submerged depth 3, uninstall and clear off 4, replace seal ring |
Great pump power consumption | 1. Stuff tightened, overheated 2. Great flow 3. Collision between rotor and case 4. Pump shaft bearing abrasion 5. Pump shaft misplaced |
1. loosen slightly 2. reduce globe valve opening 3. adjust 4. replace bearing 5. replace or adjust |
Great pump vibration | 1. impeller partially jammed 2. impeller damaged 3. little flow 4. non-concentric between pump shaft and motor. 5,bearing damaged 6, gas etching |
1. Uninstall and clear off 2, replace 3, increase opening 4, adjust 5, replace 6, change suction inlet position |