Diesel Automatic Fire Fighting Water Pump

Product Details
Customization: Available
After-sales Service: All Life Service
Warranty: 1 Year Warranty
Manufacturer/Factory
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001, ISO 14001
  • Diesel Automatic Fire Fighting Water Pump
  • Diesel Automatic Fire Fighting Water Pump
  • Diesel Automatic Fire Fighting Water Pump
  • Diesel Automatic Fire Fighting Water Pump
  • Diesel Automatic Fire Fighting Water Pump
  • Diesel Automatic Fire Fighting Water Pump
Find Similar Products

Basic Info.

Model NO.
XBC
Air Engine Type
Diesel Engine
Theory
Gas-hydraulic Hybrid Type
Transmission
Direct Connection Transmission
Structure
The Slide
Diesel Pump
Fire Fighting Pump
Pump
Diesel Water Pump
Fire Fighting Pump
Diesel Pump
Water Pump
Diesel Engine Pump
Centrifugal Pump
Fire Water Pump
Transport Package
Wood Case
Specification
SGS
Trademark
Borra
Origin
Wenzhou
HS Code
841330900
Production Capacity
500

Product Description

Diesel Automatic Fire Fight Water Pump

As per head, flow and media, the flow range: 10-870L/s, pressure range: 0.15-6MPa, diesel engine rotation speed range: 1500-2900rpm. 
Used for emergency water supply in high buildings, taper water, steel factories, wine plants, chemical factories, hotels. Automatic, full functions, good structure, easy to install and use.
as per conditions: 1-stage 1-priming centrifugal pump, high-pressure multi-stage pump, 2-priming pump.



Run conditions:
1. Altitude: ≤2500m
2. Ambient temperature: -25~55ºC

3. Ambient relative humidity: 9~95%
4. Anti-earthquake degree: degree 7
5. Flow range: 50-700(L/S)
6. Head range: 32-600m
7. Power: 18-1100KW
8. Wet part materials: cast iron, graphite cast iron, stainless steel, cast copper.



Function specifications:
Diesel engine fire pump, electric pumps and stabilized pressure pump can form an automatic voltage fire water supply system and can realize linkage with fire control center. When diesel engine fire pump group received orders, if utility without powertime, then automatically control cabinet of diesel power immediately to the starter of pump group issued open signal, the starter, enggine idle starting, then gradually adjust diesel engine accelerator and make the diesel engine speed until the rated speed. The control system will automatic monitoring of diesel engine, such as the workings of diesel oil, oil temperature, rotational speed and pump outlet pressure, etc. Through the automatic monitoring to determine whether the normal starting diesel, if starting failure criterion control system will be issued to start signal, if 13 times are starting, the automatic control system failure will be issued starting failure alarming. When diesel engine fire pump group received pipe pressure recovery or mains supplyicoil resume normal signal, pump group will rapidly slow down and in idle position monitor after a period of automatic stop.

 

Diesel Automatic Fire Fighting Water Pump
 

Technical parameters:

  Q (L/s) (MPa) n (r/min) P (Kw) η (%)
XBC3.0/5-50(65) 5 0.30 2900 4 63
XBC3.2/5-50(65) 0.32
XBC3.4/5-50(65) 0.34
XBC4.6/5-50(65) 5 0.46 2900 7.5 58
XBC4.8/5-50(65) 0.48
XBC5.0/5-50(65) 0.50
XBC7.6/5-50(65) 5 0.76 2900 15 50
XBC7.8/5-50(65) 0.78
XBC8.0/5-50(65) 0.80
XBC11/5-50(65) 5 1.10 2900 30 40
XBC12/5-50(65) 1.20
XBC12.5/5-50(65) 1.25
XBC3.0/10-65(80) 10 0.30 2900 7.5 71
XBC3.2/10-65(80) 0.32
XBC3.4/10-65(80) 0.34
XBC4.6/10-65(80) 10 0.46 2900 15 67
XBC4.8/10-65(80) 0.48
XBC5.0/10-65(80) 0.50
XBC7.6/10-65(80) 10 0.76 2900 22 59
XBC7.8/10-65(80) 0.78
XBC8.0/10-65(80) 0.80
XBC11/10-65(80) 10 1.10 2900 37 54
XBC12/10-65(80) 1.20
XBC12.5/10-65(80) 1.25
XBC3.0/25-80(100) 25 0.30 2900 15 76
XBC3.2/25-80(100) 0.32
XBC3.4/25-80(100) 0.34
XBC4.6/25-80(100) 25 0.46 2900 22 74
XBC4.8/25-80(100) 0.48
XBC5.0/25-80(100) 0.50
XBC7.6/25-80(100) 25 0.76 2900 37 69
XBC7.8/25-80(100) 0.78
XBC8.0/25-80(100) 0.80
XBC11/25-80(100) 25 1.10 2900 75 69
XBC12/25-80(100) 1.20
XBC12.5/25-80(100) 1.25
XBC13/25-80(100) 25 1.30 2900 90 57
XBC14/25-80(100) 1.40
XBC15/25-80(100) 1.50
XBC3.0/45-125 45 0.30 2900 22 73
XBC3.2/45-125 0.32
XBC3.4/45-125 0.34
XBC4.6/45-125) 45 0.46 2900 37 77
XBC4.8/45-125 0.48
XBC5.0/45-125 0.50
XBC7.6/45-125 45 0.76 2900 55 80
XBC7.8/45-125 0.78
XBC8.0/45-125 0.80
XBC11/45-125 45 1.10 2900 90 70
XBC12/45-125 1.20
XBC12.5/45-125 1.25
XBC2.8/55-150 55 0.28 1450 30 78
XBC3.0/55-150 0.30
XBC3.2/55-150 0.32
XBC4.6/55-150 55 0.46 1450 45 75
XBC4.8/55-150 0.48
XBC5.0/55-150 0.50
Diesel Automatic Fire Fighting Water PumpDiesel Automatic Fire Fighting Water PumpDiesel Automatic Fire Fighting Water Pump
Diesel Automatic Fire Fighting Water PumpDiesel Automatic Fire Fighting Water Pump

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier