Customization: | Available |
---|---|
After-sales Service: | Worldwide |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Flow | Up to 720m3/h |
Head | Up to 500 m |
Speed | Up to 3500 RPM |
Power | Up to 500 kW |
Caliber | DN25 - DN500 mm |
Fault | Cause | Solution |
The pump cannot suck water, pressure gauge & vacuum gauge vibrating | 1. Insufficient water pouring 2. Leak between pipe and meter 3. Suction is too high |
1, check a leak in the bottom valve. 2, Tighten the leaked part 3, reduce suction |
The pump cannot suck, high vacuum is shown in the vacuum gauge | 1, bottom valve closed or jammed 2, Too great water suction resistance 3, filter jammed |
1, check bottom valve 2, replace water suction pipe 3, clear off the filter |
Pressure gauge works, no water outcome | 1. Great outlet water pipe resistance 2. Wrong rotation direction 3. Outlet pipe valve closed 4. impeller jammed |
1. check or shorten water pipe 2, check the motor, adjust 3, open the valve and clear off the impeller |
Cannot reach designed flow | 1. air sucked 2. Water level drops, submerged depth is not enough 3. impeller jammed 4. rotor torn and worn |
1, check leak part and clear off 2, prolong water inlet pipe, increase the submerged depth 3, uninstall and clear off 4, replace seal ring |
Great pump power consumption | 1. Stuff tightened, overheated 2. Great flow 3. Collision between rotor and case 4. Pump shaft bearing abrasion 5. Pump shaft misplaced |
1. loosen slightly 2. reduce globe valve opening 3. adjust 4. replace bearing 5. replace or adjust |
Great pump vibration | 1. impeller partially jammed 2. impeller damaged 3. little flow 4. non-concentric between pump shaft and motor. 5, bearing damaged 6, gas etching |
1. Uninstall and clear off 2, replace 3, increase opening 4, adjust 5, replace 6, change suction inlet po |