Basic Info.

Model NO.
XBC
Air Engine Type
Diesel Engine
Theory
Gas-hydraulic Hybrid Type
Transmission
Direct Connection Transmission
Structure
The Slide
Pump
Diesel Water Pump
Diesel Pump
Split Case Pump
Water Pump
Diesel Engine Pump
Fire Pump
Fire Fighting Pump
Transport Package
Depends on Requirement
Specification
SGS
Trademark
BORRA
Origin
China
HS Code
8413709990
Production Capacity
50000 Pieces/Year

Product Description


Split Case Diesel Fire Fighting Water Pump

The diesel engine fire pump, IS series single-stage, S, SOW series of new single-stage & dual-stage, TSWA, D series. Domestic or foreign diesel engines used have compact structure, easy to maintain and use, automatic control, reliable.
New Design Fire Fighting Pump in ShandongThe diesel engine fire pump, IS series single-stage, S, SOW series of new single-stage & dual-stage, TSWA, D series. Domestic or foreign diesel engines used have compact structure, easy to maintain and use, automatic control, reliable.

Technical parameters:
Flow range: 10-800L/S
Pressure range: 0.2-2.2MPA
Rotation speed: 1500r/min    1800 r/min    2400 r/min    3000 r/min

Work range:
Ambient pressure :> 90KPa
Ambient temperature: 50C-400C
relative humidity:≤80%
In abnormal conditions, greater diesel engine power is needed to match the pump.

Characteristics:
(1). Three start modes:
1. Manual start: switch between manual, automatic interlink by hand, manual start:
2. automatic/manual mode: start fail warning 5-10-15S;
3. Emergency manual direct start: in failure, emergency manual start.
(2). Automatic run: when pump receives fire signals, if motor fire pump electric power supply system is off or phase loss, and pump cannot start normally, diesel engine fire pump will automatically start, as soon as the electric power supply system recovers or motor pump can start normally, it will be switched to the motor pump automatically.
(3). automatic stop: when fire signal is off, diesel engine fire pump will delay and stop.
(4). Storage battery self-charging: storage battery can be charged by industrial power diesel engine charging motor.
(5). Perfect indication system: prepared start, manual start, automatic start, run, stop, storage battery charging, ultra-speed, diesel engine lubricant oil pressure too low, booster oil pressure too low, diesel engine lubricant oil temperature too low, diesel engine cooling water temperature too low, storage battery voltage too low, fuel oil level too low (shortage).
(6). Perfect warning or safeguard system: 3-fail start warning, ultra-speed warning, lubricant oil warning, booster oil warning, cooling water temperature warning, lubricant oil warning, automatic charging system warning , storage battery warning , storage battery warning, oil level warning.
(7). Good indicators: diesel engine lubricant oil pressure, diesel engine rotation speed, storage battery charging current, storage battery charging voltage.
(8). Direct coupling: diesel engine is connected with pump with coupler, compact structure, little faults, little faults, little vibration, easy to install.
9. Pressure, flow range: IS series 1-stage 1-priming, S\SOW series 1-stage 2-priming, TSWA\D series multi-stage pump.
10. Flow, pressure regulation: diesel engine pump, with mechanical regulator or electronic regulator, when pump flow, head are not correct, you can change the diesel engine rotation speed.
11. Water preheat system: AC220V cooling water preheat system, to keep work under 50C.
12. Storage batteries: a standby system.
13. maintenance-free storage batteries: it is not needed to refill liquids frequently.
14. Automatic timed monitor test: standby fire system, automatic test and warning.
Note: designed as per requirements.
Configuration:
1, pump: IS series of single-stage single-suction, S, SOW series 1-stage dual-suction, TSWA, D series multi-stage.
2, diesel engine: 1-cylinder, 2-cylinder, 3-cylinder, 4-cylinder, 6-cylinder, 8-cylinder, 12-cylinder diesel engine.
3, rotation speed: 1500r/min, 1800r/min, 2400r/min, 3000r/min.
4, accessories: Filter muter, cooling system, fuel tank, seat, heat-exhaust water tank, storage battery, and charger. (Preheat system)
5, control cabinet: microcomputer, PLC, sensors, automatic control cabinet.
Technical parameters:
Diesel engine pump Rate flow
m3/h
Rate head
m
Rated rotation speed
r/min
Pump type
XBC8.0/13.9 30-50-60 84-80-75 2900 IS80-50-250
XBC7.0/13.0 47 70 2900 IS80-50-250A
XBC6.0/12.2 44 60 2900 IS80-50-250B
XBC8.5/11.7 42 85 2900 IS80-50-315B
XBC11.0/13. 47 110 2900 IS80-50-315A
XBC12.5/13.9 30-50-60 128-125-123 2900 IS80-50-315
XBC5.0/27.8 60-100-120 54-50-47 2900 IS100-65-200
XBC6.0/23.9 86 60 2900 IS100-65-250B
XBC7.0/25.8 93 70 2900 IS100-65-250A
XBC8.0/27.8 60-100-120 87-80-75 2900 IS100-65-250
XBC10.0/25.0 90 100 2900 IS100-65-315B
XBC5.0/55.6 120-200-240 58-50-45 2900 IS125-100-200
XBC6.0/48.1 173 60 2900 IS125-100-250B
XBC12.5/27.8 60-100-120 133-125-118 2900 IS100-65-315
XBC8.0/55.6 120-200-20 87-80-72 2900 IS125-100-250
XBC12.5/55.6 120-200-240 133-125-120 2900 IS125-100-315
XBC11.0/52.8 190 110 2900 IS125-100-315A
XBC9.2/48.1 173 92 2900 IS125-100-315B
XBC5.0/111 240-400-460 55-50-45 1450 IS200-150-400
XBC5.0/28 100 50 1450 IS125-100-400
XBC5.0/28 200 50 1450 IS150-125-400
XBC4.6/10 30-36-42 50-46-40 1450 75TSWA×4
XBC5.7/10 30-36-42 62-57-50 1450 75TSWA×5
XBC6.9/10 30-36-42 75-69-60 1450 75TSWA×6
XBC8.0/10 30-36-42 87-80-70 1450 75TSWA×7
XBC9.2/10 30-36-42 100-92-80 1450 75TSWA×8
XBC10.3/10 30-36-42 112-103-90 1450 75TSWA×9
XBC6.2/19.2 62-69-80 64-62-56 1450 100TSWA×4
XBC7.8/19.2 62-69-80 81-78-70 1450 100TSWA×5
XBC9.3/19.2 62-69-80 97-93-84 1450 100TSWA×6
XBC10.9/19.2 62-69-80 113-109-98 1450 100TSWA×7
XBC6.4/25 72-90-108 69-64-60 1450 125TSWA×3
XBC8.6/25 72-90-108 92-86-80 1450 125TSWA×4
XBC10.8/25 72-90-108 115-108-100 1450 125TSWA×5
XBC6.0/43 119-155-191 65-60-55 1480 150TSWA×2
XBC9.0/43 119-155-191 97-90-82 1480 150TSWA×3
XBC12.0/43 119-155-191 129-120-109 1480 150TSWA×4
XBC8.6/77.8 190-280-346 95-86-77 1480 200D1-43×2
XBC12.9/77.8 190-280-346 142-129-115 1480 200D1-43×3
XBC12.0/125 400-450-500 123-120-114 1480 D450-60III×2
XBC11.4/139 450-500-550 120-114-108 1480 D500-57×2
XBC12.0/200 550-720-850 132-120-108 1480 D720-62×2
XBC5.0/60 150-216-260 59-50-45 1480 D216-25×2
XBC7.5/60 150-216-260 88-75-67 1480 D216-25×3
XBC10.0/60 150-216-260 118-100-90 1480 D216-25×4
XBC12.5/60 150-216-260 147-125-112 1480 D216-25×5
XBC6.5/134 360-485-612 71-65-56 1450 250S65
XBC9.0/219 590-790-936 93-90-82 1450 300S90
XBC7.8/210 576-756-918 86-78-70 150 300S90A
XBC6.7/200 540-720-900 72-67-57 1450 300S90B
XBC5.8/219 576-790-972 65-58-50 1450 300S58
XBC5.0/204 529-735-893 55-50-42 1450 300S58A
XBC12.5/351 850-1260-1660 140-125-100 1450 350S125
XBC11.2/328 787-1181-1538 120-112-86 1450 350S125A
XBC9.6/305 697-1098-1363 106-96-77 1450 350S125B
XBC7.5/351 972-1260-1440 80-75-65 1450 350S75
XBC6.5/325 900-1170-1332 70-65-56 1450 350S75A
XBC5.5/300 813-1080-1202 59-55-46 1450 350S75B