Mobile Sewage Diesel Dewatering Pump Set
The diesel sewage pump is a product successfully developed on the basis of repeated research on similar foreign technologies. It can be equipped with manual and automatic control. Compared with similar domestic products, the diesel sewage pump has the characteristics of simple structure, strong sewage discharge capacity, high efficiency, and energy-saving, convenient use and maintenance, etc., and has a wide range of application markets and development prospects.
Feature :
It is suitable for large flow and short-distance water delivery. It has higher efficiency, larger displacement, and lower energy consumption. Equipped with a vacuum-assisted system, it can be self-priming without irrigation.
Application :
1-farmland drainage and
2- irrigation,
3- construction engineering,
4- urban water supply and drainage.
Conditions of Use :
1- The ambient temperature is ≤50ºC, the medium temperature is ≤80ºC, and the special requirements can reach 200ºC.
2- The pH value of the medium is 6-9 for cast iron, 2-13 for stainless steel, and 1-13 for lining with fluoroplastics.
3- The media weight does not exceed 1240kg/m3.
4- The self-priming height cannot exceed the specified value of 4.5-5.5 meters, and the total length of the suction pipe is ≤10 meters.
5- Through capacity, The diameter of suspended particles is 50% of the diameter of the pump, and the fiber length is 5 times the diameter of the pump.
Advantage :
1- Simple structure, easy to use and maintain, with high efficiency, small and light.
2- Transmission mode: direct and variable-speed. The actuators: Electric Motor and diesel engine. In the purchase order, specify actuator type (power, rotations), to confirm spindle coupler or belt specification.
3- Pump direction: from the pump inlet side, the impeller normally is counterclockwise, (650CHW -5, -7, and 10 pumps clockwise).
4- Every spar part supplier is chosen strictly based on excellent quality
5- Complete production procedures, strict test center, good package
Technical Parameters:
|
Q |
H
(m) |
n
(r/min) |
(mm) |
η
(%) |
N(kW) |
(NPSH)c(m) |
W
(kg) |
(m3/h) |
(L/S) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
150CHW-5 |
180 |
50 |
5 |
1450 |
150 |
150 |
82 |
2.99 |
4 |
2.7 |
60 |
150CHW-6 |
180 |
50 |
6 |
1450 |
150 |
150 |
82 |
3.59 |
5.5 |
3 |
68 |
|
223 |
62 |
9.2 |
1800 |
150 |
150 |
82 |
7.07 |
7.5 |
4 |
68 |
150CHW-8 |
180 |
50 |
8 |
1450 |
150 |
150 |
82 |
4.78 |
5.5 |
2.7 |
60 |
150CHW-12 |
180 |
50 |
12.5 |
2900 |
150 |
150 |
82 |
7.47 |
11 |
6 |
55 |
200CHW-5 |
360 |
100 |
5 |
1450 |
200 |
200 |
81.5 |
6.01 |
7.5 |
4 |
105 |
200CHW-8 |
360 |
100 |
8 |
1450 |
200 |
200 |
83.5 |
9.39 |
11 |
4 |
105 |
200CHW-10 |
360 |
100 |
7 |
1200 |
200 |
200 |
83.5 |
8.22 |
11 |
4 |
130 |
|
450 |
125 |
10 |
1450 |
200 |
200 |
83.5 |
14.68 |
18.5 |
5 |
130 |
: |
500 |
139 |
12.2 |
1600 |
200 |
200 |
83.5 |
19.91 |
30 |
5.5 |
130 |
200CHW-12 |
360 |
100 |
12.5 |
1450 |
200 |
200 |
83.5 |
14.68 |
18.5 |
4 |
105 |
250CHW-5 |
540 |
150 |
5 |
1180 |
250 |
250 |
82 |
8.97 |
11 |
4 |
190 |
250CHW-7 |
450 |
125 |
7 |
980 |
250 |
250 |
84 |
10.22 |
15 |
4 |
168 |
250CHW-8 |
444 |
123 |
5.4 |
970 |
250 |
250 |
84 |
7.78 |
11 |
2.7 |
190 |
: |
540 |
150 |
8 |
1180 |
250 |
250 |
84 |
14.01 |
18.5 |
4 |
190 |
: |
664 |
184 |
12.1 |
1450 |
250 |
250 |
84 |
26 |
30 |
6.4 |
190 |
250CHW-11 |
450 |
152 |
4.8 |
980 |
250 |
250 |
84 |
7 |
11 |
4 |
169 |
: |
650 |
180 |
11.6 |
1450 |
250 |
250 |
84 |
24.37 |
30 |
6 |
169 |
: |
720 |
200 |
14.3 |
1600 |
250 |
250 |
84 |
33.38 |
37 |
6.5 |
169 |
250CHW-12 |
540 |
150 |
12.5 |
1180 |
250 |
250 |
84 |
21.88 |
30 |
4 |
190 |
300CHW-5 |
792 |
220 |
5 |
970 |
300 |
300 |
83 |
12.99 |
15 |
4 |
230 |
300CHW-8 |
792 |
220 |
8 |
970 |
300 |
300 |
85 |
20.3 |
22 |
4 |
230 |
300CHW-8A |
581 |
161 |
3.9 |
730 |
300 |
300 |
84 |
7.48 |
11 |
3 |
230 |
: |
780 |
217 |
7 |
980 |
300 |
300 |
84 |
18.08 |
22 |
4 |
230 |
: |
1035 |
288 |
12.3 |
1300 |
300 |
300 |
84 |
42.17 |
55 |
5 |
230 |
300CHW-12 |
792 |
220 |
12.5 |
970 |
300 |
300 |
85 |
31.72 |
37 |
4 |
230 |
350CHW-8 |
745 |
207 |
4.4 |
730 |
350 |
350 |
85.5 |
10.44 |
15 |
4 |
330 |
: |
1000 |
278 |
8 |
980 |
350 |
350 |
85.5 |
25.5 |
30 |
5 |
330 |
400CHW-7 |
1260 |
350 |
6.8 |
730 |
400 |
400 |
86 |
27.13 |
30 |
4 |
486 |
: |
1692 |
470 |
12.3 |
980 |
400 |
400 |
86 |
65.9 |
75 |
5 |
486 |
400CHW-10 |
1400 |
389 |
9.94 |
730 |
400 |
400 |
86 |
44.3 |
55 |
4 |
496 |
: |
1880 |
522 |
18 |
980 |
400 |
400 |
86 |
107.1 |
110 |
5 |
496 |
500CHW-6 |
1980 |
550 |
6.2 |
580 |
500 |
500 |
87 |
38.4 |
55 |
5.5 |
770 |
: |
2492 |
692 |
9.8 |
730 |
500 |
500 |
87 |
76.4 |
95 |
6 |
770 |
650CHW-5 |
3312 |
920 |
5.1 |
485 |
650 |
650 |
85 |
54.1 |
75 |
5.5 |
1940 |
: |
4032 |
1120 |
7.55 |
590 |
650 |
650 |
85 |
97.5 |
115 |
6 |
1940 |
650CHW-7 |
3400 |
944 |
6.5 |
450 |
650 |
650 |
88 |
68.4 |
90 |
5.3 |
1940 |
. |
3663 |
1017 |
7.6 |
485 |
650 |
650 |
88 |
86.1 |
100 |
5.5 |
1940 |
. |
4457 |
1238 |
11.18 |
590 |
650 |
650 |
88 |
154.2 |
180 |
6 |
1940 |
650CHW-10 |
4000 |
1111 |
14 |
590 |
650 |
650 |
88 |
173.3 |
180 |
6 |
1940 |
. |
3322 |
923 |
9.7 |
490 |
650 |
650 |
88 |
99.7 |
115 |
5.5 |
1940 |
700CHW-8 |
4500 |
1250 |
7.8 |
490 |
700 |
700 |
88 |
108.7 |
130 |
4.5 |
. |
800CHW-10 |
5980 |
1661 |
12.2 |
490 |
800 |
800 |
88 |
225 |
250 |
5.5 |
3433 |
800CHW-16 |
7200 |
2000 |
17.7 |
590 |
800 |
800 |
88 |
394.6 |
450 |
6.5 |
3433 |
1200CHW-2.5 |
9600 |
2667 |
2.5 |
154 |
1200 |
1200 |
88 |
74.3 |
100 |
2 |
9850 |
1200CHW-6.6 |
15584 |
4329 |
6.6 |
250 |
1200 |
1200 |
88 |
318 |
350 |
4 |
9850 |
1200CHW-9.6 |
18700 |
5194 |
9.5 |
300 |
1200 |
1200 |
88 |
550 |
630 |
6 |
9850 |
|
Start, running and stop
Start
1. First of all, pour water into pipes, to make the pump and inlet pipe filled with water. The pipes shall be sealed, no air leaked. (no-water inside start is forbidden)
2. Close globe valve and cock on outlet pipe, to reduce start currency.
3. Rotate the rotor by hand, lubricate the bearing and check the pump impeller, seal the ring, if it cannot rotate, you shall not start.
4. Try to start, motor rotation direction shall be as same as the arrow direction on the pump.
5. When the rotor works normally, open gradually the outlet globe valve, adjust for the work conditions required.
Running
1. Observe the reading in meters, keep it running around the flow and head shown on the nameplate.
2. Regularly check, motor currency value shall not exceed rated currency value.
3. Pump bearing temperature shall not exceed 75ºC, and shall not be 35ºC higher than ambient environment.
4. To start, loosen the stuff cap. Adjust later when started.
5. In case of fragile component abrasion, replace in time.
6. When any abnormal happens, immediately stop and check.
Stop
1. Close the globe valve on the outlet pipe, close the vacuum gauge cock.
2. Stop the motor, and close the pressure cock.
3. In Winter, drain the liquid in the pump completely to avoid frozen cracks.
4. When you will not use it for a long time, uninstall the pump, clean, and lubricate.
Troubleshooting
Fault |
Cause |
Solution |
The pump cannot suck water, pressure gauge & vacuum gauge vibrating |
1. Insufficient water pouring 2. Leak between pipe and meter 3. Suction is too high |
1, check a leak in the bottom valve. 2, Tighten the leaked part 3, reduce suction |
The pump cannot suck, high vacuum is shown in the vacuum gauge |
1, bottom valve closed or jammed 2, Too great water suction resistance 3, filter jammed |
1, check bottom valve 2, replace water suction pipe 3, clear off the filter |
Pressure gauge works, no water outcome |
1. Great outlet water pipe resistance 2. Wrong rotation direction 3. Outlet pipe valve closed 4. impeller jammed |
1. check or shorten water pipe 2, check the motor, adjust 3, open the valve and clear off the impeller |
Cannot reach designed flow |
1. air sucked 2. Water level drops, submerged depth is not enough 3. impeller jammed 4. rotor torn and worn |
1, check leak part and clear off 2, prolong water inlet pipe, increase the submerged depth 3, uninstall and clear off 4, replace seal ring |
Great pump power consumption |
1. Stuff tightened, overheated 2. Great flow 3. Collision between rotor and case 4. Pump shaft bearing abrasion 5. Pump shaft misplaced |
1. loosen slightly 2. reduce globe valve opening 3. adjust 4. replace bearing 5. replace or adjust |
Great pump vibration |
1. impeller partially jammed 2. impeller damaged 3. little flow 4. non-concentric between pump shaft and motor. 5, bearing damaged 6, gas etching |
1. Uninstall and clear off 2, replace 3, increase opening 4, adjust 5, replace 6, change suction inlet po |
Borra Technology Co., Ltd.
Borra Technology co., Ltd., founded in 1995, owns a top-rank design, production, sales, and service team, and modern production lines, to manufacture various self-priming pumps, movable diesel pumps, diesel Self-Priming dirt drain pumps, diesel fire pumps units, diesel mini-pumps.
Certificate :
Services:
1. One year or 1000 working hours guarantee of the whole machine except for wear parts;
2. Technical support by email the whole day;
3. Calling service;
4. User's manual available;
5. Installation guide for clients from both China and abroad;
6. Maintenance and replacement service;
FAQ:
Q1: Are you a reliable company?
A1: Bora is located in Wenzu, a beautiful city in Zhejiang Province, China. we have many years of manufacturing experience,
we can supply all types of fire protection solutions, Drainage and sewage solution, and other pump products.
We have an independent factory and trade office.
Q2: how to deliver the portable diesel water pump
A2: We can offer our equipment by containers or bulk ship.
Q3: How to pay for the portable Diesel water pump?
A3: We can accept T/T, L/C and soon
Q4: why choose borra company?
A4: We have an independent factory and foreign trade office. so we can design high-quality portable generators
and water pumps according to clients requirements and our price is reasonable.
Contact Us
If you are interested in our products or have any questions about our products, we are very honored to serve you